Yes, level sensors can be added to recreational-vehicle gray and black water tanks, and both retrofit kits and factory-style systems exist; the main constraint is that the sensor technology must tolerate the tank's contents, because wastewater coatings, solids, and tank shape defeat many sensors that work fine in fresh water.
The short version: for black tanks especially, external (through-the-wall) capacitive or ultrasonic sensors, or a float/reed switch designed for waste tanks, are the usual practical choices; conductive-probe sensors that rely on the liquid closing a circuit are the type most likely to foul and give false readings. The question does not specify the RV model, tank material, existing monitor panel, or whether the tank is accessible, and those details determine which kit will physically fit and wire in.
Why the answer depends on sensor principle, not just "adding a sensor"
A level sensor is not a single thing. Several physically different devices all get called "level sensors," and they behave very differently in a tank full of soap scum, toilet paper residue, and anaerobic sludge.
Conductive (resistance) probes dip into the tank and register a level when the conductive liquid bridges probes at different heights. They are cheap and common on older RVs. In wastewater they are the classic failure point: grease, paper, and mineral film coat the probes, so the circuit closes when the tank is not actually that full, or stays open when it is. Float switches use a buoyant element that rises with the liquid and trips a switch. They are simple and reliable in clean water, but in a black tank solids and paper can jam the float or hold it down. Capacitive sensors detect the change in capacitance as liquid rises near a sensing surface. Many are mounted on the outside of the tank wall, so they never contact the waste. That avoids fouling but makes them sensitive to wall thickness and material, and to sludge clinging to the inside face. Ultrasonic and radar/time-of-flight sensors measure the distance to the liquid surface from above. They never touch the waste, but foam, condensation on the transducer, and irregular tank geometry can distort the echo. Pressure/head sensors infer level from the hydrostatic pressure at the bottom of the tank. They need a consistent liquid density and a clean pressure port, and they are more common in marine and industrial tanks than in RV retrofits. Load cells or weight-based systems weigh the tank or the whole vehicle; they are elegant but rare in RVs and awkward to retrofit around a fixed tank.
So "can I add a sensor?" is really "which sensing principle survives this tank?" The answer is yes for most RVs, but not with every sensor.
The gray-tank versus black-tank distinction matters
Gray water—sink, shower, and sometimes galley drainage—carries soap, hair, and food grease. Black water carries sewage, toilet paper, and the products used to break it down. Both are hostile to exposed electronics, but black tanks are the harder case.
A through-wall capacitive sensor on a gray tank often works acceptably because gray water is relatively uniform and the tank walls stay cleaner. On a black tank, the same sensor can read high when a film of sludge coats the inside of the wall, or read low when a crust of dried solids insulates the sensing surface. That is why some retrofit kits offer separate gray- and black-tank sensor heads or recommend a different mounting for each.
Float and reed switches can work in black tanks if they are the enclosed, guided-float type and the tank is flushed regularly, but they are the components most likely to need service. Conductive probes in a black tank are the least forgiving choice and the most common source of "my gauge always says full" complaints.
What a retrofit usually involves
A typical aftermarket level-sensor installation has four parts: the sensor head or probe, a mounting method, wiring to a display or to the existing monitor panel, and calibration.
1: Access. The tank must be reachable—often through a compartment, under a bench, or behind a panel. Some tanks have a factory sending-unit hole or a spare port; others require drilling a new hole, which means knowing the wall thickness and what is behind it. 2: Mounting. External capacitive pads glue or clamp to the outside of the tank wall. Internal probes and floats require a threaded fitting, a gasket, and a hole sized to the fitting—work that must be done with the tank empty and clean, and ideally off the vehicle. 3: Wiring and display. Sensors need power and a signal path to a gauge. Many kits include their own small display; some are designed to feed an existing panel, but only if the panel's input type matches (for example, a resistance-based gauge expects a variable resistor, not a switching sensor). 4: Calibration. Empty and full reference points must be set for the actual tank, because tank shapes are rarely simple rectangles and the sensor's "full" position depends on where it is mounted.
The installation is within the reach of a confident DIY owner for external sensors, but internal probes on a black tank are a job many owners hand to an RV technician, both because of the drilling and because of the waste-handling. The exact procedure, torque values, and sealant recommendations are specific to the kit and tank manufacturer and are not something to guess.
Limits, ambiguities, and what the question leaves open
Several things are genuinely unknown here, and they change the answer:
Tank material and wall thickness. Capacitive through-wall sensors are calibrated for a range of wall materials; a steel or thick polyethylene tank may need a different sensor than a thin plastic one. Existing monitor panel. If the RV already has a gauge, the cheapest path may be replacing only the sending unit with one the panel accepts—but only if the panel's electrical specification is known. Tank shape. A tank with internal baffles or a stepped shape can make a single-point sensor read misleadingly. Whether the tank is accessible without removal. This is often the deciding practical factor. Purpose. A "full/not full" warning is easier than a continuous 0–100% readout; a simple switch can be far more robust than an analog sensor.
What is answerable without those details: retrofit sensors exist, they are commonly installed on both gray and black tanks, and the reliable choices in wastewater are the ones that either avoid contact with the waste or use a waste-tolerant mechanical design.
Accuracy and safe expectations
No sensor is maintenance-free in a black tank. Even good through-wall sensors can drift as residue builds up, and any internal sensor can be fouled by paper or hardened sludge. A realistic expectation is a useful indicator that may need occasional cleaning or recalibration, not a laboratory-grade measurement. Owners should also treat any level reading as advisory: a stuck sensor that reads "empty" when the tank is full is a real risk, so visual checks and conservative dump schedules still matter.
Because this is ordinary equipment and maintenance guidance rather than medical, legal, or financial advice, no professional disclaimer applies; the main caution is the practical one about working safely around waste tanks and following the specific kit's installation instructions.